B-Capta Sensors
Proven safe and reliable
B-Capta is based on an accurate and reliable optical-based technology, improved to guarantee the highest level of accuracy and reliability when measuring patient blood gas parameters,even in long and complex cardiopulmonary bypass procedures.
Accurate and continuous measurements
B-Capta allows accurate monitoring of pO2 and temperature in the Arterial line and saturation, HCT /Hb and temperature in the Venous line. It does not provide calculated parameters, but only measured values to guarantee accurate monitoring.
Pediatric and adult procedures with the same sensor
The B-Capta Arterial and Venous sensors fit all disposable cuvette sizes, allowing the perfusionist to use the same sensor for both pediatric and adult procedures.
They are easy to couple with the relevant disposable cuvettes as they are identified by different color-coded labels.
Sensor Module
Ready-to-go
B-Capta does not require any calibration procedure to set the device measurements, allowing
the perfusionist to save time during device set up, especially in emergency cases.
Easy parameters alignment with ABL measurement
B-Capta's innovative technology embeds a compensation algorithm to easily adjust the blood
gas parameters according to those of the Hospital Laboratory Blood Gas Analyzer (ABL) to
ensure trending accuracy during the entire procedure.
S5 Display
Easy and intuitive user interface
The Venous and Arterial parameters monitored by B-Capta are shown in the S5 system panel.
The B-Capta user interface is intuitive and easy to use: easy parameter configuration and
menu navigation, clearly displayed parameters and accessible system panel layout.
S5 user-experience
The B-Capta display is integrated in the S5 heart-lung machine allowing the perfusionist to:5
- Do without additional external monitors and holders that may obstruct the perfusionist's view during the procedure
- Have all patient and procedure parameters in the same location, reducing the levels of stress felt by the perfusionist during the procedure.
Visual and audible warnings
B-Capta has an integrated warning system based on thresholds selected by the user, providing
visual and audible indicators when parameters fall outside said thresholds.
Connect
Accurate perfusion records
Throughout the entire procedure, the B-Capta blood gas values are automatically transferred to Connect, LivaNova’s data management system, enabling the perfusionist to maintain accurate perfusion procedure records.
Support the implementation of Goal-Directed Perfusion (GDP) therapy in Connect1,2
The B-Capta Arterial and Venous parameters can be used to feed the GDP formulas in Connect, as they are continuously transferred to Connect during the procedure through the S5 serial interface.1,2
Cuvettes
Disposable solution tailored to customers’ needs
The Venous and Arterial disposable cuvettes are available as sterile stand-alone disposables or included in the Perfusion Tubing Systems, both pre-connected and not.
The Venous cuvettes are available in three sizes: 1/2", 1/4", 3/8"
The Arterial cuvettes are available in two sizes: 3/8", 1/4"